W & W Manufacturing X3 & X6 Battery Charger User Manual


 
& X6 SpecificationsX
Number of stations
QuickTest:
Standard Tests:
Battery Voltage
Charge/Discharge current:
Maximum charge power X3
Maximum Discharge power: X3
Power Management
Chemistries
Charge and End of Charge Detection Protocols:
Display:
Batter y Adapters:
Data Ports:
Line Voltage:
Input Current:
Output: X3 X6
Dimensions and Weight: X3 X6
Options Available:
3 6
#1 #1 & 4
Takes approximately 3min.
Checks Impedance
Checks voltage min/max
Checks discharge at different rates
Utilizes an algorithm to determine capacity range.
Charge only
3 6
Discharge only
3 6
Cycle :1,2,3
3 6
Auto
3 6
Condition
3 6
Impedance
1 1 & 4
:1.2 to 15V Max. Number of cells: Nickel based : 12 cells, Li-ion: 4 cells
50mA to 4A in 50mA steps
: 55W/station , 60 W total 58 W/station,100W totaL
25W/station 25W/station, ,75W tota 75W total l
: The X3 & X6 automatically regulates which station will receive max. Power during high pwr demands.
: Lion, NiCD and NiMH
Li -ion, Constant current - Constant voltage Detection is achieved at C/11. Where (C) = capacity of Batt.
Nickel based battery: Constant current, with negative deltaVDetection.
20x22 Backlit LCD
Quick Connect Adapter Cups for ease of changing Adapters (No tools required)
Five Memory locations, each can be programmed for Li-ion, NiCD or NiMH
Fifth memory location is field programmable, for all parameters
RS-232 interface to P.C. And Serial Printer
100 T O 240 VAC 50 to 60 Hz
2A
24V@2.5A 24V@4.16A
Lengt
Lengt
h
h
4.5”(110.25mm)
4.5”(110.25mm)
Widt
Widt
h
h
13”(318.5mm)
24.5”(622.3mm)
Dept
Dept
h
h
9”(220.5mm)
9”(220.5mm)
Weigh
Weigh
t
t
6.5lb(2.96kg)
11.3lb(5.2kg)
P.C. Software, Serial Printer, Universal Adapter and Power Supply (24V@4.16A)
All Specifications are subject to change without notice.070217
Station Std Power Supply Hi Power Supply
X3
*
5
Learn Mode
This mode when selected will allow a battery’s parameters to be created for new battery models.
A battery “Adapter Cup” holds a total of 5 battery profiles for parameter storage; four are preprogrammed
with OEM information for a particular battery series. The fifth profile can be modified by the “Learn
Mode”. During entry into the “Learn Mode”, Battery Chemistry, Capacity, and the number of Cells are
prompted for data entry. Follow the Directions below to enter data for the Learn Mode.
Data Range
Chemistry (Lithium Ion, Nickel Cadmium, and Nickel Metal Hydride)
Capacity 100 - 4000 maH
# Of Cells 1-12 NiCd and 1-4 Li-ion
ACTION
Display After “Turn On”
NO ACTION
NO ACTION
NO ACTION
NO ACTION
PUSH
PUSH
PUSH
PUSH BUTTON ONCE
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
BATTERY TYPE =
LITHIUM ION
SELECTED CAPACITY =
1800 MAHR
CELL COUNT =
2 CELLS
ENTER THE NEW CHARGE
RATE: 1000 MA
PASS / FAIL LEVEL =
80% OF CAPACITY
ENTER NEW DIS -CHRG
RATE: C/2
NOMINAL IMPEDANCE =
250 mOHMS
ACCEPT DEVIATION =
35%
LION 1CELL 1800MAH
CHRG: 1000MA C /:2
STORING NEW
CONFIGURATION
EMPTY
EMPTY
LEARN MODE
SELECTED
BATT STATUS: UNKNOWN OR GOOD
<FUNCTION> TO CHANGE
INSERT BATTERY
**
**
Learn Mode Precautions
A good battery must be used to calibrate a
battery’s profile. OEM batteries have unique
profiles that should not be used when testing
non-OEM batteries. For each new non-OEM
battery, create a new profile. The factory
settings can not be modified in the field,
however by utilizing the LEARN MODE
function one can learn a non-OEM battery.
It is very important that the battery you are
using the LEARN MODE function for must be
at least 95% of the stated capacity and a
Impedance test should be performed on
the battery in question and entered when
requested in the LEARN MODE. It is a good
idea to set the acceptable deviation to
35% to begin with. The learning of a good
non-OEM battery will enable you to perform
a QUICK TEST (QT) in station #1 of the X3 and
stations #(1) and #(4) of the X6.
PUSH
READY
LEARN MODE COMPLETE
REMOVE BATTERY
REMOVE BATTERY
(**) APPEARS ONLY WHEN A (GOOD) BATTERY IS BEING LEARNED!
Important: It is important that when testing
an UNKNOWN BATTERY in the learn mode that
you select the UNKNOWN state as opposed to
the GOOD state until the battery has been
certified to be equal to or greater than 95% of
it’s rated capacity, then perform an Impedance
test and record the results, repeat the learn
mode with: BATT STATUS: as GOOD. Once a
good battery is learned, you will be able to
perform a QUICK TEST in station (1) of the X3
and on stations (1) and (4) of the X6.
.
*
*
16
SELECTING “ LEARN “
AND RESULTS
X3 X6
Stations
Stations
X6 55W/station, 120W total 58W/station, 200W total
X6 25W/station, 150W total 25W/station 150W total