Air leak from
safety
valve.
Possible defect in safety
valve.
Operate safety valve
manually by pulling on
ring. If valve still leaks,
it should be replaced.
Knocking Noise.
Malfunctioning check valve.
Remove and clean, or
replace.
Compressor is not
supplying enough
air to operate
accessories.
Prolonged excessive use of
air.
Compressor is not large
enough for air requirement.
Restricted air intake filter.
Hole in hose.
Check valve restricted.
Air leaks.
Decrease amount of air
usage. Check the
accessory air
requirement. If it is
higher than the SCFM
or pressure supplied by
your air compressor,
you need a larger
compressor. Clean or
replace air intake filter.
Do not operate the air
compressor
Regulator knob
has continuous air
leak.
Regulator will not
shut off air outlet.
Pressure release valve on
pressure switch has not
unloaded head pressure.
Damaged regulator.
Replace regulator.