Wagan 2601 Welding System User Manual


 
Elite
400W Pro Pure Sine Inverter by Wagan Tech
®
www.wagan.com
9
©2012 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks used by Wagan Corporation.
10
User’s Manual—Read before using this equipment
TROUBLESHOOTING
PROBLEM: Low or No Output Voltage – Fault LED Lit
Reason Solution
Poor contact with battery, inverter
terminals, or DC socket.
Clean terminals thoroughly. Reinstall
and tighten. Clean DC socket with non-
metallic abrasive emery stick.
PROBLEM: No Output Voltage – No LEDs Lit
Reason Solution
Blown fuse. Check vehicle’s Accessory Socket Fuse.
If the fuse is blown, replace with the
same type and rating fuse.
PROBLEM: Inverter Auto Shut Down – Fault LED Lit
Reason Solution
Battery voltage is below 9.5 volts. Charge or replace battery.
Inverter is too hot (thermal shut down
mode).
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the inverter to
the specified TrueRated
power max
output.
PROBLEM: Inverter Shut Down – Fault LED Lit
Reason Solution
Equipment being operated draws too
much power.
Do not use the equipment with this
inverter; use a higher wattage inverter.
PROBLEM: Continuous Buzzing Sound
Reason Solution
Input voltage is below 10.5 volts . Keep input voltage above 10.5 volts .
Poor or weak battery condition. Recharge or replace battery.
Poor or loose cable connection. Inspect terminals and tighten all
connections.
Inadequate power being delivered to
the inverter or excessive voltage drop.
Use heavier gauge DC cables.
Keep cable length as short as possible.
DISPOSAL/RECYCLING OF INVERTER
Electronic products are known to contain materials that are toxic if improperly
disposed. Contact local authorities for disposal and recycling information.