39
OPERATING MANUAL
VERSION 03/2013 ORDER NUMBER DOC 2310799
7.2.3 DECOMMISSIONING AND CLEANING
Notice
The device should be cleaned for maintenance purposes. Ensure that no remaining
material dries and sticks.
Procedure:
1 Carry out pressure relief of the material and air -> Chapter 7.2.2.
2 Basic cleaning -> carry out the steps in Chapter 6.5.3.
3 Maintain the gun according to the operating manual.
4 Clean and check the suction system and the suction lter.
5 Clean the outside of the system.
6 Put the whole system back together.
7 Check the level of the separating agent -> Chapter 6.5.2.
8 Fill the system with ushing agent as laid down in Chapter 7.1 "Filling with Working
Material".
Brittle lter pressure regulator!
The container on the lter pressure regulator becomes brittle
through contact with solvents and can burst.
Flying parts can cause injury.
Do not clean the container on the lter pressure regulator with
solvent.
WARNING
Gas mixtures can explode if there is an incompletely filled
pump!
Danger to life from ying parts.
Ensure that the pump and suction system are always completely
lled with ushing agent or working medium.
Do not spray the device empty after cleaning.
WARNING