Windsor QQS34SP Sander User Manual


 
8
SABER/STRIDE II 28/34 98570 7/14/98
MACHINE OPERATION
DOUBLE SCRUB
Floors which are heavily soiled or have thick accumulations
of floor finish may not clean sufficiently with one pass. In
these cases it will be necessary to double scrub.
To double scrub, begin scrubbing as usual, but after push-
ing number 1, press the squeegee button to turn off vac mo-
tor. Manually raise the squeegee. Make the first pass over
the surface being cleaned with the solution on, and brush-
es down and squeegee up. This allows the solution to stay
in contact with the soil while loosening the surface accumu-
lation with the brushes. Allow time for the first application
to stay in contact with floor. Length of time between the first
and second pass depends on amount of accumulation and
the type of chemical being used. A second scrubbing with
the squeegee down and again the solution and brushes on
will further loosen soil. The additional application of solu-
tion will further assist the difficult cleaning job.
EMPTYING AND CLEANING TANKS
RECOVERY TANK
1. Park the SABER/STRIDE II next to a floor drain.
Drain hose is on left rear corner of machine.
2. Turn “OFF” the key switch and set the machine
parking brake.
3. Unhook the large drain hose from the retainer and
unscrew T-handle on plug enough to release the plug,
then lower hose in direction of the drain. Recovered
solution will come out with some force.
4. The recovery tank should then be flushed out with
clean water. Hinge solution tank open to access
recovery tank.
5. If machine is to be stored, leave solution tank hinged
open.
SOLUTION TANK
1. Drain solution tank by unhooking the small solution
drain hose from left rear of tank.
2. Loosen T-handle on plug enough to remove plug.
Allow tank to drain completely.
3. Flush tank of all chemical solution.
4. Run several gallons of clean water through system.
NOTE: Never allow solution to remain in tank. Damage to
tank, seals and valves could occur.