Xantrex Technology 20 Battery Charger User Manual


 
8
Operation Status
INVERT - Green LED
• When the LED is solid green, the unit is
in invert mode. This occurs by pressing the
INVERT switch.
• When the LED is blinking slowly (1 time
per second), the inverter is in standby with AC
power applied and the transfer switch engaged
• When the LED is OFF, the inverter is
OFF.
CHARGE - Green LED
• When the LED is solid green, the unit is
in the charge mode and external AC power is
being supplied.
• When the LED is blinking slowly, (1 time
per second) the charger is ready, but external
AC power is not available.
• When the LED is OFF, the charger has
been manually turned OFF. This can only be
accomplished while AC power is being
supplied since the charger will automatically
restart each time AC power is applied.
OPERATION
The Freedom Inverter/Charger provides
120 volt AC power from auxiliary DC batteries,
automatic battery charging and automatic AC
transfer switching between an external AC
source and inverter mode AC output.
The Freedom Inverter/Charger may be
operated with or without a remote control panel
or Link instrument.
When operating the inverter/charger with-
out a Freedom or Link remote control panel:
Front Panel Controls and Indicators
INVERT MODE
The INVERT push-button switch is
located on the front of the unit.
• To turn the inverter ON, press and hold
the INVERT switch until the INVERT LED is
solid green. The unit is now inverting. Press
the INVERT switch again to turn the inverter
OFF. Note: The charge LED will be blinking
slowly indicating Charger ready status but
external AC power is not connected.
CHARGE MODE
The CHARGE push-button switch is located
on the front of the unit.
When external AC is applied to the AC
input of the unit, the charger automatically
turns ON. The CHARGE LED will be solid
green. The unit is now charging. Press the
CHARGE switch again to turn the charger OFF.
The charger defaults to ON when operating
without a remote or with the Freedom Remote
Control Panel. Refer to the Link manual when
using a Link remote control panel.
INVERT
CHARGE
REMOTE
TSC
INVERT / WET
CHARGE / GEL1
LOW BATTERY / GEL 2
OVERTEMP
OVERLOAD / AGM
Status LEDs
Front Panel
STATUS LEDs
Each Status LED performs two functions,
providing operation status and battery type
selection.
INVERT
CHARGE
Freedom Marine 20