Xantrex Technology 50A24V Battery Charger User Manual


 
Onboard Control and Status Display Panel
975-0401-01-01 1–13
Input Voltage Operating and Derating
When there is an AC input out of range warning in the lower
range between 90–108 Vac, the Truecharge™ 2 Battery
Charger derates to 80% of maximum current.
However, when AC input increases above 108 Vac up to
255 Vac, maximum current returns to 100% capacity.
Furthermore, the Truecharge™ 2 Battery Charger will
continue to operate at 100% of maximum current, even while
there is an AC input out of range warning in the upper range
between 256–265 Vac.
Battery and Charger Temperature Thresholds
Figure 1-5
Battery and Charger Temperature Thresholds
Ambient Temperature
derating to
80% Imax.
Charger
ALARM set
Charger
FAULT set
Charger
ALARM reset
Charger
FAULT reset
-25 -20 -15 -10 -5 0 5 10 20 30 40 50 6015 25 35 45 55 65 70 °C
COLD (default 0 °C) WARM (default 25 °C) HOT (default 35 °C)
ALARM set ALARM set
FAULT set FAULT set
FAULT reset ALARM reset ALARM reset FAULT reset
-25 -20 -15 -10 -5 0 +5 +10 +20 +30 +40 +50 +60 +70 °C