Xantrex Technology 806-1054 Battery Charger User Manual


 
975-0390-01-01 9
Freedom Inverter/Charger Configuration
Setting Battery Types on the Main Unit
You can attach different types of lead-acid batteries to the Freedom
HF. Before installing batteries make sure that you configure the unit
to optimize the charging process.
The settings can be changed by adjusting the dip switches found on
the main unit behind the display panel.
To adjust the battery type setting:
By default the battery type is set to Flooded (OFF|ON).
1. Detach the Display Panel to expose the Dip Switches.
2. Use the tip of your fingernail or a small screw driver with a flat
tip to adjust the switches.
Battery
Type
Dip Switch
Setting
Switch 1|Switch 2
Bulk/
Absorption
Float
Fixed OFF|OFF 13.5 13.5
Flooded OFF|ON (default) 14.4 13.5
GEL ON|OFF 14.2 13.8
AGM ON|ON 14.3 13.4
Figure 2 Dip Switches (Default Settings Shown)
ONOFF
Switch 1 | Switch 2
Freedom HF InvChg Owners Guide.book Page 9 Tuesday, April 29, 2014 12:10 PM