Xantrex Technology 806-1840 Welding System User Manual


 
975-0390-01-01 25
Battery Charging
Table 4 illustrates the battery charging voltage and current settings for the
Freedom HF 1000 model and all Freedom HF 1800 models.
Table 5 illustrates the battery charging voltage and current settings for the
Freedom HF 1055 models.
Table 3
Battery Charging Status LED
Status LED Display Screen Condition
Solid GREEN

Battery is FULL.
Flashing GREEN
.
(where 12.8 is an example of battery
voltage)
Battery is in BULK
CHARGE.
.
(where 14.2 is an example of battery
voltage)
Battery is in ABSORPTION
CHARGE.
Solid RED
to
See Table 1, “Error Codes
Displayed on the Display
Panel Screen” on page 33.
Table 4
Battery Charging Voltage and Current Settings
Battery
Type
Bulk/
Absorption
(Volts)
Float
(Volts)
Charge
Current
(Amps)
Float
Current
(Amps)
Flooded 14.4 13.5 2
5
a
, 10, 20
40
b
a. Applicable to Freedom HF 1000 models only.
b. Applicable to Freedom HF 1800 models only.
2
2
a
5
a
GEL 14.2 13.8 2
5
a
, 10, 20
40
b
2
2
a
5
b
AGM 14.3 13.4 2
5
a
, 10, 20
40
b
2
2
a
5
b
Fixed 13.5 13.5
2, 5
a
, 10, 20,
40
b
2, 5
a
, 10, 20,
40
b
Table 5
Battery Charging Voltage and Current Settings
Battery
Type
Bulk/
Absorption
(Volts)
Float
(Volts)
Charge
Current
(Amps)
Float
Current
(Amps)
Flooded 14.4 13.5 5, 15, 35
55
2
5
GEL 14.2 13.8 5, 15, 35
55
2
5
AGM 14.3 13.4 5, 15, 35
55
2
5
Fixed 13.5 13.5 5, 15, 35,
55
2
5
Freedom HF InvChg Owners Guide.book Page 25 Thursday, November 24, 2011 11:20 AM