Fixed Voltage Mode
The fixed voltage mode setting is meant to be used as a power supply or
battery eliminator. It is not meant for charging batteries. The battery type,
battery temperature, and equalize switches are all ignored in fixed voltage
mode. The remote battery temperature sensor does not compensate the
voltage, but the battery over-temperature shutdown is still active.
Optional Accessories
Battery
Temperature
Sensor
The remote Battery Temperature Sensor (BTS) automatically adjusts the
charge according to the temperature of one of the batteries. With a BTS
installed, the unit provides a more accurate temperature-compensated
charge for the battery to which the sensor is attached.
Remote panel The remote panel allows you to monitor the charging progress of two
batteries or battery banks, the total charge current, and charger status from
a convenient location.
Indicator Lights and Settings on the Front Panel
This section describes the parts of the front panel of the Truecharge 20+.
Figure 1-1 shows the front panel. Descriptions are provided in Table 1-1
Figure 1-1 Front panel of Truecharge 20+ battery charger