Installing the MVS-8100D 1
18 Cognex MVS-8100D and CDC Cameras Hardware Manual
3. Connect wires from your TTL devices to the signal and ground terminals of cable
300-0358 using the pin numbering in Table 6
4. Use your Cognex software documentation to map the signal name from Table 6 to
the software commands that enable, disable, set the value of, toggle, and set the
input/output direction of each line.
Pin
Signal Name on
MVS-8100D1
Signal Name on
MVS-8100D2 and
MVS-8100D3
1 TTL_BI_1 TTL_BI_1
2 TTL_BI_2 TTL_BI_2
3 TTL_BI_3 TTL_BI_3
4 TTL_BI_4 TTL_BI_4
5 TTL_BI_5 TTL_BI_5
6 TTL_BI_6 TTL_BI_6
7 TTL_BI_7 TTL_BI_7
8 TTL_BI_8 TTL_BI_8
9 NC TTL_BI_9
10 NC TTL_BI_10
11 NC TTL_BI_11
12 NC TTL_BI_12
13 TTL Ground TTL Ground
14 TTL Ground TTL Ground
15 NC NC
16 NC NC
Table 6. Pin numbering of cable 300-0358’s 16-pin terminal end
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15