Section 9 ... Auto Power Down Feature
§ In order to conserve battery life the S2000T printer features a auto power down timer.
The power down timer defaults to 20 seconds on initial power up.
§ The auto power down timer can be set by sending recognized command string or disabled
by activating the <RTS> input line or setting the auto power down timer to zero.
§ The auto power down command string:
ESC M n n 0 CR
27 77 2 digit ASCII 48 thru 57 48 13
Disable timer: 27 77 48 48 48 13
Set to 99 seconds: 27 77 57 57 48 13
§ The first two characters "ESC" and "M" are command header characters. The next two
digits ASCII "01" through "99" sets the time-out in seconds, while the last two characters
are the command terminator characters.