_J_JJJJJJ_JJJ_J_J_J_
....................... SECTION 5 _ .....................
........................I SERVICE TECH. INFORMATION
jjjjjJJJJJJJJJJJJJJ_JJJJ
A. TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self-
diagnostic function for the electrical system, except
for input power and water meter. The computer
monitors electronic components _ _r-r-
and circuits for correct opera-
tion. If a malfunction occurs, an 5.
error code appears in the face-
f
plate display. ....
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECTbut-
ton. SELECT remains operational so the service per-
son can make the MANUAL INITIATED ELEC-
TRONIC DIAGNOSTICS (below) to further isolate
the defect, and check the water meter.
CODE
Err1, Err3,
Err4
Err5
POSSIBLE DEFECT
MOST LIKELY .I[ _ LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
hiqh torque
faceplate timer (PWA)
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug transformer 2. Correct defect 3. Plug
in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.
MANUAL INITIATED ELECTRONICS
DIAGNOSTICS
_To enter diagnostics...
- -from a error code display, press the SELECT 1
button.
--from a time display, press and hold the SE-
LECT I button for 3 seconds.
valve posi_onindicator
(F¢It_d _lne flashing)
r minu_ of brinklgUrn9
I_._d tat] +-- c_,,-=_r'="
t _ whenvalve madaes
m, _w_._ww= brin' iJ_on) VALVE ROTATING
_==_ r_g pos FROM 11RECHARGE
-"-'- , ,.
posi_,o_swl_chindk:atot THIS EXAMPLE)
(dosed)
You will see one of the following displays. All of the
displays show what position the valve is in, if the
turbine is operating, and the position switch open or
closed status.
ValVe position ilTdJCatO¢
I sir_e thelast
|turbine o_unt
\
positionswitchindicator
(open)
VALVE IN SERVICE
POSITION
POSITION SWITCH STATUS: With the valve in ser-
vice, or any of the recharge cycles, the switch indica-
tor will show open -.',--. While the valve is rotating
from 1 position to another, the indicator will show
the switch closed --,_. A defect is probable if indica-
tions vary from this pattern.
WATER METER TURBINE: With soft water in use,
the turbine flow rate display continually repeats a
000 to 140 count for each gallon of water passing
through the turbine. The display will remain a
steady...000 if soft water is not in use (open a nearby
soft water faucet to check).
valve po/__on
.--+ 0].2,,
_y., _ ware meter
VALVe IN A RECHARGE
POSITION {FILL IN THIS
EXAMPLE)
If you don't get a reading in the display, with facuet
open, pull the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.
5-2
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line