31
Care and maintenance
10.04 Parameter settings
Parameter settings are described in the separate operations manual for
the drive, and may only be changed by qualifi ed technicians!
See Chapter 3 Specifi cations
*
Adjustment see Chapter 8.05 Basic position of the machine drive unit.
10.04.01 Parameter list for PicoDrive with control unit P41 PD2
Group
Parameter
Description
User lever
Setting range
Set value
1
105 Speed for start backtackl B, C 300 - 2000 1500
110 Speed for end backtack B, C 300 - 2000 1500
6
606 Speed min B, C 30 - 300 180
607 Speed max. B, C 300 - 6000
▲
609 Cutting speed 1 B, C 60 - 300 220
668 Thread wiper/thread blower
1 = on; 0 = off
B, C 0 - 1 0
7
700 Needle position 0
(needle reference position
B, C 0 -255 *
702 Needle position 1 (needle lowered) B, C 0 - 255 79
703 Needle position 2 (take-up lever raised) B, C 0 - 255 222
705 Needle position 5 (end cutting signal 1) B, C 0 - 255 175
706 Needle position 5 (start cutting signal 2) B, C 0 - 255 135
707 Needle position 9 (start thread tension
release/start thread catcher)
B, C 0 - 255 190
797 Hardwaretest (OFF / ON ), B, C OFF
799 Selected machine class C 1 - 3 1
8
800 Rotating direction of the motor C 0 - 1 1
802 Main drive reduction ratio
0 = 1:1, 1 = variable
C 0 - 1 0
9
985 Switch on angle for thread trapper B, C 0 -255 67
986 Switch off angle for thread trapper B, C 0 -255 206
989 Thread trapper at beginning of seam
0 = no
1 = yes
2 = Thread clamp with sewing foot lift
B, C 0 - 2 0