CAUTION
DO NOT REVERSE THE POLARITY: RISK OF SHORT CIRCUIT AND DAMAGE
TO THE ELECTRICAL SYSTEM.
WARNING
SPENT BATTERIES ARE HARMFUL FOR THE ENVIRONMENT. COLLECTION
AND DISPOSAL SHOULD BE CARRIED OUT IN COMPLIANCE WITH CURRENT
REGULATIONS.
Long periods of inactivity
If the vehicle has not been used for long periods, it is necessary to periodically re-
charge the battery, bearing in mind that the battery tends to go completely flat within
around three months. The battery must be recharged with a current load equal to 1/10
of the battery rated capacity (~ 1A ), for a period not longer than 8 hours. For this
operation contact an Authorised Service Centre. When refitting a removed battery,
make sure that all terminals are properly connected.
03_19
Fuses (03_19, 03_20, 03_21, 03_22, 03_23)
The electrical system has twelve fuses divided into two fuse boxes to protect the dif-
ferent installation circuits. One of them is inside the battery compartment «A» and the
other is at the internal side of the right footrest «B».To have access, loosen the screw
«C» and remove the plastic cover. The chart shows the position and characteristics
of the fuses in the vehicle.
57