AB Soft XT 14000 Battery Charger User Manual


 
4
Recond (Lamp 5) (only on MULTI XS 25000 and MULTI XT 14000)
This mode is used to recover deeply discharged flooded batteri
es. Recondition of deep discharged batteries. The voltage
increases with reduced current for a limited time period. The higher voltage starts some gassing and mixing of the acid, which is
beneficial for both battery capacity and expected life. Note that the battery could emit explosive gas during Recond. R
econd is
performed between Analysis and Ma
intenance.
INDICATORS
Lamp Description
0
Fault mode, the charging is discontinued. For fault causes,
see below.
1
Start mode
2
Bulk charging
3
Absorption charging
4
Maintenance charging
5
Supply (Only on MULTI XS 25000 and MULTI XT 14000)
6
Recond reconditioning of completely discharged batteries.
(Only on MULTI XS 25000 and MULTI XT 14000)
A
Charging without temperature compensation.
B
Mains voltage connected
C
Normal (Only on MULTI XS 25000 and MULTI XT 14000)
D
Supply (Only on MULTI XS 25000 and MULTI XT 14000)
E
Recond (Only on MULTI XS 25000 and MULTI XT 14000)
Fault mode
The charger goes to fault mode if the time for gradual start has been exceeded or if the battery’s self-discharge is too high.