AB Soft XT 14000 Battery Charger User Manual


 
6
PARAMETERS
PROGRAM DESCRIPTION
Current (Amperes)
Voltage (Volts
)
Desulphation Soft Start Bulk Absorption
Recovers a
sulphated battery
Tests the battery
condition
Bulk charge
Peak charge with
minimal fluid loss
MULTI XS 25000
MODE Desulphation Soft Start Bulk Absorption
NORMAL
or
RECOND
YES Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h. 14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.
SUPPLY
XS 25000
MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 10 A for 4 h until the
voltage reaches 12 V.
25 A for max 20 h. 14.4 V until 4 h after the
current dropped to 3 A,
max 12 h.
MULTI XT 14000
MODE Desulphation Soft Start Bulk Absorption
NORMAL
or
RECOND
YES Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h. 28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.
SUPPLY
XT 14000
MODE Desulphation Soft Start Bulk Absorption
PRESET YES Max 6 A for 4 h until the
voltage reaches 24 V.
14 A for max 20 h. 28.8 V until 4 h after the
current dropped to 2 A,
max 12 h.