AB Soft XT 14000 Battery Charger User Manual


 
5
TEMPERATURE COMPENSATION
MULTI XS 25000, XS 25000, MULTI XT 14000 and XT 14000 have a sensor cable placed together with the battery cables. The
units will automatically adjust the charging voltage if the temperature deviates from +25 C. A high temperature lowers the voltage
and freezing conditions is handled by higher voltage.
The temperature is best measured on or very close to the battery. Therefore always place the sensor as close to the battery as
possible when charging. The sensor cable could be prolonged or cut to length with the same functionality. A short-circuited or
disconnected sensor is indicated by lamp A. The charging voltage is then adjusted to the +25 C condition.
SPECIFICATION
MULTI XS 25000
XS 25000
MULTI XT 14000
XT 14000
Voltage AC 170-260 VAC, 50-60 Hz.
Charging voltage 14.4 V 28.8 V
Charging current 25 A max. 14 A max.
Current, mains 2,9 A rms (at full charging current)
Back Current Drain* <2Ah per month
Current ripple** <4 %
Ambient temperature - 20°C to + 50°C Output power is automatically reduced at higher temperatures.
Cooling Fan
Charger type Eight-step, fully automatic
Battery types All types of 12 V lead-acid batteries
(WET, MF, AGM and GEL).
All types of 24 V lead-acid batteries
(WET, MF, AGM and GEL).
Battery capacity 40-500Ah 28-300Ah
up to 500 Ah maintenance
Protection class IP 44 (Outdoor use)***
Weight
1,4 kg
*) Back current drain is the current that the charger drains from the battery if the AC cord is disconnected.
**) The quality of the charging voltage and charging current are very important. High current ripple heats the battery and ages
the positive electrode. High voltage ripple can damage other equipment connected to batteries. The battery chargers from CTEK
produces very high quality voltage and current with low ripple.
***) IP 44 cannot be guaranteed if the charger is not positioned horizontally with the long side or top side turned up.