Banner ac-Voltage Series Stud Sensor User Manual


 
2 P/N 69942 rev. A
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Installation
Guide
MINI-BEAM
®
ac-Voltage Series
Models with suffixes E, EL, EPD, R, RL, RPD, LV,
LVAG, LP, D, C, C2, CV, CV2, and CVG
Models with suffix DBZ and W
Sensor Features
(shown with gasketed acrylic cover removed)
Models with suffix F and FV
Models with suffix FP
Gain (Sensitivity) Adjustment Screw
Alignment Indicator Device (AID)*
Light/Dark Operate Select Switch
Clockwise: Light Operate
(outputs conduct when sensing
light is received).
Counterclockwise: Dark Operate
(outputs conduct when sensing
light is not received).
*U.S. Patent no. 4356393
12.2 mm (0.48")
Mounting Peg
(ø 6.3 mm x 2.5 mm)
ø 3 mm Clearance (2)
M18 x 1 x 15 mm Thread
(Mounting Nut Supplied)
3.2 mm
(0.13")
27.4 mm (1.08")
30.7 mm
(1.21")
24.1 mm
(0.95")
19.1 mm
(0.75")
66.0 mm
(2.60")
2 m (6.5') Cable
Bezel
18.0 mm
(0.71")
51.8 mm
(2.04")
13.2 mm (0.52")
M18 x 1 x 19 mm Thread
(Mounting Nut Supplied)
Fiber Optic Fitting
69.9 mm
(2.75")
31.2 mm (1.23"
)
54.8 mm
(2.16")
Fiber
Optic
Fitting
22.3 mm
(0.88")
16.2 mm
(0.64")
QD Models
20.0 mm
(0.79")
12 mm Thread
Quick-disconnect
NOTES:
• Please observe proper ESD precautions
(grounding) when adjusting Gain pot or
LO/DO switch.
• When turning the Light/Dark Operate Select
switch, be careful not to damage the small
tabs on the switch.
Dimensions