-8-
REMOVING AND INSTALLING
THE SOFT BAND HANDLE (Old Style)
Always use auxiliary
handle for maximum
control over torque reaction or kick-back.
Using the tool without the handle could
cause loss of control.
To remove, insert a flat tip screwdriver
between tab and clip as shown, rotate
screwdriver counter-clockwise lifting tab until
clip releases from housing (Fig. 6).
To attach, first insert one side of latch into tool
housing, then firmly push the other latch into
housing while applying pressure in direction
of arrow until clip locks securely into housing
(Fig. 6a).
Repeat this procedure on opposite end of
strap.
CHANGING THE COLLET
The 1/8" collet is used with 1/8" diameter
bits, the 1/4" collet is used with 1/4" diameter
bits and the 5/32" collet is used with 5/32"
diameter bits. To change collets, first
remove the bit. Continue to loosen and
unscrew the collet nut until you can remove it
from the tool. Remove the collet and replace
it with the other (Fig. 4). (Each collet is
double-ended, and either end is acceptable
to use.) By hand, re-tighten the collet nut
around the collet in a clockwise direction.
You are now ready to insert a new bit as
instructed in Installing Bits (Fig. 2 or 3).
COLLET
COLLET
NUT
OUTPUT SHAFT
FIG. 4
TAB
CLIP
HOUSING
FIG. 6
FIG. 6a
LATCH
CLIP
!
WARNING
REMOVING AND INSTALLING THE HARD
AUXILIARY CONTROL HANDLE
Turn the tool OFF and unplug it. Firmly
grasp the tool. Lift open handle release
button cover, depress release button and
remove handle (Fig. 5).
Gently engage the two (2) front latches on
handle into the tool and push handle until it
snaps securely into place.
HANDLE
RELEASE
BUTTON
COVER
HANDLE
RELEASE
BUTTON
FIG. 5
RZ 2610917368 9-04 10/1/04 8:09 AM Page 8