Campbell Hausfeld FP2400 Air Compressor User Manual


 
30 Sp
battery for 7 to 9 hours. If the unit is
used too long after the yellow light
comes on, recharging time could
take up to 20 hours and the battery
life may be shortened.
4. Do not operate the unit while
recharging with the 120-volt AC
adapter. Unit will not run while
recharging.
BATTERY INDICATOR LIGHTS
Green, yellow and red lights show the
battery condition. The green light
indicates a charged battery. The yellow
light indicates the battery is low and
needs recharging. If the red light is on
at any time, the unit will not operate.
Do not leave the
compressor
unattended while the unit is running.
Turn unit off to
allow compressor to
cool for 20 minutes after 20 minutes of
continuous operation. If not cooled
properly, the compressor will overheat.
After the battery is charged, the
compressor is ready for use. If the
battery has not been charged, see
section on 120-VOLT AC CHARGING
!
CAUTION
!
WARNING
3
Model FP2400
Pre-Operation
NOTE: The compressor will not operate
when the charger is plugged into the
charger jack.
FUSE REPLACEMENT
NOTE: The compressor is shipped
with fuse removed. To install fuse,
open accessory storage door and
insert fuse into plug.
When replacing the fuse, make sure the
compressor is turned off and nothing is
connected to it. (See Specifications and
Features sheet for location of fuse.)
NEVER replace a blown fuse with a
fuse having a higher rating.
120-VOLT AC RECHARGING
To recharge the battery using the 120-
volt AC adapter, follow the subsequent
procedures:
1. Push the power switch to the off
position and insert the 120-volt AC
recharging adapter into the AC
charge input socket located next to
the power switch.
2. Plug the charger into a 110/120-volt
electrical outlet. The red and yellow
lights will flash, indicating the
battery is recharging.
3. Charge the compressor for 14 to 16
hours before the initial use. After
subsequent uses, recharge the
before continuing.
TIPS FOR LONGER BATTERY LIFE
- Charge the battery for 14 hours
before first using the compressor.
Use the charging adapter provided.
- Recharge within 48 hours of use.
- Make sure battery is fully charged
when storing.
- Recharge every 3-5 months, even
during periods of light or no use.
- This product uses a sealed,
rechargeable lead acid battery.
The compressor has a small air reservoir
and the pump is controlled by a
pressure switch. When the internal
pressure reaches approximately 100 psi,
the pump will turn back on.
1. There is a 20 amp automotive type
cartridge fuse inside the accessory
storage cover. If the compressor fails
to operate at all, check the fuse.
2. Internal safety valve will release if
pressure exceeds 160 psi. This
indicates a compressor problem. If
this happens, do not operate
compressor. Take it to an authorized
Campbell Hausfeld Service Center.
3. There is a tank drain on the bottom
of the compressor to remove
moisture from the tank. Pressure
should be be below 15 psi before
opening drain valve.
4. Make sure that there are no leaks in
the hose, attachments and fittings. If
there are leaks, the pump will cycle
as it replaces the lost air and will run
the battery down.
MOISTURE IN COMPRESSED AIR
Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the fittings and
hose. When using a paint spray or sandblast gun, this water will be carried from
the tank through the hose, and out of the gun as droplets mixed with the spray
material.
IMPORTANT: This condensation will cause water spots in a paint job,
especially when spraying other than water based paints. If sandblasting, it will
cause the sand to cake and clog the gun, rendering it ineffective. A filter in
the air line (MP3105), located as near to the gun as possible, will help
eliminate this moisture.
www.chpower.com
ON OFF OFF Full to Normal
OFF ON OFF Weak-Needs Recharging
OFF OFF ON Exhausted-Needs Recharging IMMEDIATELY
Unit Will Not Operate
OFF FLASHING FLASHING Unit Is On Charge and Will Not Operate
GREEN YELLOW RED BATTERY
LIGHT LIGHT LIGHT INDICATION
Battery must be
charged before
initial use and if the yellow light comes
on. If the power is totally drained from
the battery and not recharged, the
battery may not be rechargeable.
Recharge the unit every 3 to 6 months
even if the unit has not been used.
NOTICE
Compresor de aire sin cable
Garantía Limitada
1. DURACION: A partir de la fecha de compra por el comprador original tal como se especifica a continuación: Productos Estándard (Standard
Duty) - Un año, Productos Resistentes (Serious Duty) -Dos años, Productos Robustos (Extreme Duty) - Tres años.
2. QUIEN OTORGA ESTA GARANTIA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030
Teléfono: (800) 543-6400
3. QUIEN RECIBE ESTA GARANTIA (EL COMPRADOR): El comprador original (que no sea un revendedor) del producto Campbell Hausfeld.
4. PRODUCTOS CUBIERTOS POR ESTA GARANTIA: Cualquier compresor de aire Campbell Hausfeld.
5. COBERTURA DE LA GARANTIA: Los defectos substanciales de material y fabricación que ocurran dentro del período de validez de la garantía.
6. LO QUE NO ESTA CUBIERTO POR ESTA GARANTIA:
A. Las garantías implícitas, incluyendo aquellas de comercialidad E IDONEIDAD PARA FINES PARTICULARES, ESTAN LIMITADOS A LO
ESPECIFICADO EN EL PARRAFO DE DURACION. Si el compresor de aire es empleado para uso comercial, industrial o para renta, la garantía
será aplicable por noventa (90) días a partir de la fecha de compra. La garantía de los Compresores para Contratistas - Productos Robustos
(Extreme Duty) no queda limitada a los noventa (90) días cuando se los usa en aplicaciones de contratistas. La garantía de los compresores
de cuatro cilindros de una y dos etapas, no está limitada a noventa (90) días si éstos se utilizan para trabajos comerciales o industriales. En
algunos estados no se permiten limitaciones a la duración de las garantías implícitas, por lo tanto, en tales casos esta limitación no es
aplicable.
B. CUALQUIER PERDIDA DAÑO INCIDENTAL, INDIRECTO O CONSECUENTE QUE PUEDA RESULTAR DE UN DEFECTO, FALLA O
MALFUNCIONAMIENTO DEL PRODUCTO CAMPBELL HAUSFELD. En algunos estados no se permite la exclusión o limitación de daños
incidentales o consecuentes, por lo tanto, en tales casos esta limitación o exclusión no es aplicable
C. Cualquier falla que resulte de un accidente, abuso, negligencia o incumplimiento de las instrucciones de funcionamiento y uso indicadas
en el (los) manual(es) que se adjunta(n) al compresor.
D. Los servicios requeridos antes de la entrega tales como: ensamblaje, aceite o lubricantes y ajustes.
E. Artículos o servicios normalmente requeridos para el mantenimiento del producto, tales como:lubricantes, filtros, empaques, etc.
F. Los motores de gasolina están específicamante excluidos de la cobertura de esta garantía limitada. El comprador debe seguir las clausulas
de la garantía otorgada por el fabricante del motor de gasolina que se suministra con el producto.
G. Artículos adicionales no cubiertos bajo esta garantía:
1. Todos los Compresores
a. Cualquier componente dañado durante el envío o cualquier daño ocasionado por haber instalado u operado la unidad bajo
condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o daños ocasionados por el contacto con
herramientas o los alrrededores.
b. Daños del cabezal o las válvulas ocasionados por la lluvia, humedad excesiva, agentes corrosivos u otros contaminantes.
c. Daños de apariencia que no afecten el funcionamiento del compresor.
d. Tanques oxidados, incluyendo pero no limitado al óxido debido al drenaje inadecuado u agentes corrosivos en el ambiente.
e. Motores eléctricos, válvulas de chequeo y presostatos después del primer año a partir de la fecha de compra.
f. Llaves de drenaje
g. Daños debidos al alambrado incorrecto o conexión a cicuitos con voltaje inadecuados para la unidad.
h. Otros artículos no enumerados pero considerados de desgaste general.
i. Presostatos, controles de flujo de aire y válvulas de seguridad cuyos parametros fijados de fábrica se modifiquen.
2. Compresores lubricados
a. Daños del cabezal o las válvulas debidos al uso de aceites no especificados.
b. Daños del cabezal o las válvulas debidos a cualquier contaminación del aceite o por no haber seguido las instrucciones de
lubricación.
3. Compresores con bandas/ de accionamiento directo/ motores de gasolina
a. Bandas
b. Daños de los anillos debido al mantenimiento inadecuado del filtro.
c. Ajustes manuales de los instrumentos de carga/descarga y válvula de estrangulación.
7. RESPONSABILIDADES DEL GARANTE BAJO ESTA GARANTIA: Reparar o reemplazar, como lo decida el Garante, el compresor o componentes
que estén defectuosos, se hayan dañado o hayan dejado de funcionar adecuadamente, durante el período de validez de la garantía
8. RESPONSABILIDADES DEL COMPRADOR BAJO ESTA GARANTIA:
A. Suministrar prueba fechada de compra y la historia de mantenimiento del producto.
B. Entregar o enviar los compresores de aire portátiles o componentes lal Centro de Servicio autorizado Campbell Hausfeld más cercano. Los
gastos de flete, de haberlos, deben ser pagados por el comprador.
C. Tener cuidado al utilizar el producto, tal como se indica(n) en el (los) manual(es) del propietario.
9. CUANDO EFECTUARA EL GARANTE LA REPARACION O REEMPLAZO CUBIERTO BAJO ESTA GARANTIA: La reparación o reemplazo dependerá
del flujo normal de trabajo del centro de servicio y de la disponibilidad de repuestos.
Esta garantía limitada es válida sólo en los EE.UU., Canadá y México y otorga derechos legales específicos. Usted también puede tener otros
derechos que varían de un Estado a otro. o de un país a otro.