Campbell Hausfeld FP2400 Air Compressor User Manual


 
29 Sp
Maintenance
Disconnect power source
and then release all
pressure from the system
before attempting to
install, service, relocate or perform any
maintenance.
The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
compressor is used.
1. Turn power OFF (O) and clean dust
and dirt from air lines and vent
openings.
IMPORTANT: Locate unit as far from
spraying area as possible.
LUBRICATION
This is
an oilless type
compressor requiring no lubrication.
THERMAL OVERLOAD PROTECTORS
This compressor is
equipped with
automatic reset thermal overload
protectors which will shut off the
motor if it becomes overheated.
If thermal overload protectors shut
motor OFF (O) frequently, look for the
following causes.
1. Lack of proper ventilation.
2. High ambient temperature.
If the thermal
overload protector
is activated, the motor must be allowed
to cool down before start-up is possible.
The motor will automatically restart
without warning if unit is turned on.
!
CAUTION
!
CAUTION
NOTICE
!
WARNING
4
Pre-Operation (Cont.)
INDICATOR LIGHTS
The indicator lights on the unit read as
follows:
Green. Fully charged and ready to run.
Yellow. Partially discharged and
operational.
Red. Battery is low. Unit will not
operate to protect battery.
Yellow and Red Flashing. Unit is on
charge and will not operate.
Operation
BREAK-IN PROCEDURE
Do not attach air
chuck or other tool
to open end of hose until start-up has
been completed and unit checks OK.
IMPORTANT: Do not operate
compressor before reading instructions
or damage may result.
1. Make sure fuse is installed. (See Pre-
Operation section.)
2. Fully charge compressor until green
light is on.
3. Turn switch to ON (I) position and
run unit for 5 minutes to break in the
pump parts.
4. Attach hose to compressor.
5. Attach chuck or other tool to open
end of hose. The compressor is now
ready to use.
The switch should
be in the OFF (O)
position when connecting or
disconnecting the power cord from the
adapter jack.
Storage
Store the compressor in a room with
temperature between 65
o
F (18
o
C) and
75
o
F (24
o
C). Make sure the power switch
is in the 'Off' position.
Battery Disposal
This product contains a rechargeable
sealed lead-acid battery. The battery
pack itself is recyclable. If a battery
collection program does not exist in
!
CAUTION
!
CAUTION
your area, call 1-800-543-6400 for
battery disposal information.
The environmental laws in some states
require retailers to accept returns of
rechargeable batteries for proper
disposal. Check the state environmental
laws before disposing of this product.
Never throw the battery pack away in a
standard receptacle or have it
incinerated. Contact your local city
officials for battery disposal
information.
Regulator
1. This regulator controls air pressure to
the hose and attachment.
2. Turning knob clockwise increases air
pressure at outlet.
3. Turning counterclockwise will lower
air pressure at outlet.
Wall Mounting
This compressor is designed with an
option to be hung on a wall for
convenient storage. It can also be
operated while in the hanging position
if one of the following conditions is
met:
1. If mounted on a wall, mounting
hardware is secured into wood or
masonry with suitable fasteners.
2. If mounted on drywall or gypsum
board, toggle bolts or mounting
anchors are strong enough and are
properly secure to resist vibration
from the compressor.
On the bottom of the compressor are
three mounting points. The compressor
is designed to be hung with the hose
outlet pointed downward. Wall
hanging bracket must be installed in
position shown in Figure 2 and securely
fastened to studs or into concrete with
concrete anchor bolts.
Cordless Air Compressor
www.chpower.com
Figure 2 - Position of wall hanging
bracket
Modelo FP2400
Nº de Ref. Descripción Número de pieza Cant.
Para Ordenar Repuestos, Sírvase Llamer al Distribuidor
Más Cercano a Su Domicilio
Sírvase suministrarnos la siguiente información
-Número del modelo
-Número de Serie (de haberlo
-Descripción y número del repuesto según la lista de repuesto
Puede escribirnos a:
The Campbell Group / Parts
Department
100 Production Drive
Harrison, OH 45030
1 Juego del mango FP240031AV 1
2 Tapa para almacenaje FP240032AV 1
3 Cubierta superior FP240033AV 1
4 Interruptor On/Off (encendido/apagado)
1
5 Enchufe adaptador de CA 1
6 Fusible (20A) FP240023AV 1
7 Porta fusible
1
8 Batería FP240007AV 1
9 Ensamblaje de la bomba/motor FP240008AV 1
10 Tablero eléctrico FP240009AV 1
11 Receptor de aire FP240010AV 1
12 Juego de tubos(includes nuts and ferrules for copper tube) FP240011AV 1
13 Cubierta inferior FP240034AV 1
14 Patas FP240013AV 4
15 Presóstato FP240014AV 1
16 Ensamblaje del distribuidor FP240015AV 1
17 Soporte de montaje FP240016AV 1
18 Manómetro FP240017AV 1
19 Ventilador (incluye tapa) FP240018AV 1
20 Cargador de 120V FP240019AV 1
21 Ensamblaje de la lámpara FP240020AV 1
22 Juego de accesorios para inflado FP204008AV 1
23 Manguera de 7,62 m (25’) MP285100AV 1
24 Juego de reparación de la bomba FP240022AV 1
25 Válvula de seguridad V-215103AV 1
26 Juego de tornillo (incluye pernos de montaje de la
bomba/motor y tornillos de la cubierta) FP240024AV 1
27 Valvula de chequeo FP204010AV 1
No se muestran
En el tablero eléctrico (Ref. Nº 10)
Modelo de cabezal FP240000AV