Set-Up
LUBRICATION
This tool requires NO lubrication for normal operation. However, lubrication will NOT
harm the tool.
The work surface can become damaged by excessive lubrication.
MINIMUM COMPONENTS REQUIRED FOR HOOK-UP
AIR COMPRESSOR: The air compressor must be able to maintain a minimum of 60 psi
when the tool is being used. An inadequate air supply can cause a loss of power and
inconsistent driving (see Chart 1).
PRESSURE REGULATOR: A pressure regulator is required to control the operating
pressure of the tool between 60 psi and 100 psi.
AIR SUPPLY HOSE: ALWAYS use air supply hoses with a minimum working pressure
rating equal to or greater than the pressure from the power source, or 150 psi,
whichever is greater. Use 1/4 inch air hose for runs up to 50 feet. Use 3/8 inch air hoses
for 50 foot run or longer (see Figure 5 and Chart 2).
HOOK-UP INSTRUCTIONS FOR STAPLER TO AIR SUPPLY
Figure 6 shows the recommended hookup for the tool.
NOTE: For better performance, install a 3/8 inch quick plug (1/4 inch NPT threads) with
an inside diameter of 0.315 inch (8 mm) on the tool and a 3/8 inch quick coupler on the
air hose.
1. With ON/OFF switch in OFF position, plug compressor into electrical outlet.
2. Close pressure regulator by turning all the way to the left. Turn compressor ON and
let it pump all the way up to automatic shut-off pressure.
3. Attach air hose to regulator outlet. Adjust pressure regulator by turning to the right
so that outlet pressure is between 60 psi to 100 psi.
4. Load fasteners into tool (See Loading/Unloading the Stapler section on page 10).
5. Point the tool in a safe direction while attaching to air hose.
6. Tool is ready for use. You may need to adjust outlet pressure to achieve proper
fastener depth.
60 psi Minimum
100 psi Maximum
Chart 1
AIR HOSE REQUIREMENTS
DIAMETER LENGTH OF RUN
1/4 inch Less than 50 feet
3/8 inch Greater than or equal
to 50 feet
Chart 2
Figure 5 - Air Hose Requirements
Interior Diameter
Rated 150 psi or greater
Quick
Coupler
Air
Hose
Figure 6 - Recommended Hookup
Tank
Pressure
Gauge
Outlet
Pressure
Gauge
Regulator
Outlet
Regulator
Quick
Coupler
Quick
Plug
Swivel
Plug