DANGER! TO PREVENT DEATH
FROM ASPHYXIATION:
Do not open gas without proper ventilation. Fix gas
leaks immediately.
Shielding gas can displace air and cause rapid loss of
consciousness and death.
Shielding gas without carbon dioxide can be even
more hazardous,
because asphyxiation can start
without feeling shortness of breath.
5. Gas shielded, solid-core wire only:
Open gas tank valve and adjust regulator/
flowmeter to flow rate indicated on chart.
6. Flip the Power Switch to the OFF position, then plug
the Welder into a dedicated, 240 V~ receptacle that
matches the plug.
The circuit must be equipped with delayed
action type circuit breaker or fuses.
7. Hold the Torch, without touching the Trigger, with the
wire and tip clearly out of the way of any grounded
objects.
Then, turn the Power Switch ON.
MIG 180
WIRE FEED WELDER
ITEM 68886
WIRE FEED SPEED
240V~
I
O
MIG 180
WIRE FEED WELDER
ITEM 68886
WIRE FEED SPEED
240V~
I
O
HOLD
TORCH
CLEAR
SAFETY MAINTENANCEBASIC WELDING WELDING TIPSSETUP