Chicago Electric 94626 Cordless Saw User Manual


 
Page 11
SKU 94626 For technical questions, please call 1-800-444-3353
Caution: Never pull the Saw backwards since the Saw Blade will climb out of the cut and
kickback will occur.
INSPECTION, MAINTENANCE, AND CLEANING
WARNING!
Make sure the Trigger Switch of the Flush Cut Saw is in its “OFF” position, and
that the tool is unplugged from its electrical outlet, before performing any
inspection, maintenance, or cleaning procedures.
1. Before each use, inspect the general condition of the Saw. Check for loose
screws, misalignment or binding of moving parts, cracked or broken parts, damaged
electrical wiring, and any other condition that may affect its safe operation. If abnormal
noise or vibration occurs, have the problem corrected before further use. Do not use
damaged equipment.
2. Before remounting the Saw Blade (2), remove all sawdust that has accumulated
around the Safety Guard (6) and Blade Guard Frame (9).
3. Regularly inspect and tighten all mounting screws and knobs.
4. Keep Saw Blade clean and sharp. Sharp blades minimize stalling and kickback.
5. Keep guards in good working order.
6. Keep motor air vent clean of dust and debris. Vacuum periodically.
7. If the tool is not operating normally, making unusual noises, or appears defective, stop
using it immediately and get it repaired.
8. Clean tool with a damp cloth and light detergent. Do not use solvents as they can
damage and crack the plastic parts.
Replacing the Carbon Brushes
1. Unscrew the Carbon Brush Covers (38).
2. Pull out the Carbon Brush (36) from each side of the Motor and examine them.
If they are worn more than half way down, replace them. (An extra set is included.) It
could be that they are simply dirty. They can be cleaned using an ink eraser.
3. Replace the Carbon Brushes (36) and Brush Covers (38).