2-11. Electrical Service Guide
Input Voltage 200 230
Input Amperes At Rated Output 30 26
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Circuit Breaker
1
, Time-Delay
2
35 30
Normal Operating
3
45 40
Min Input Conductor Size In AWG/Kcmil 10 10
Max Recommended Input Conductor Length In Feet (Meters)
97
(29)
128
(39)
Min Grounding Conductor Size In AWG/Kcmil 10 10
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 Time-Delay fuses are UL class RK5 .
3 Normal Operating (general purpose no intentional delay) fuses are UL class K5 (up to and including 60 amp), and UL class H ( 65 amp and
above).
Y Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.