Delta 638517-00 Drill User Manual


 
11
LOCKING SWITCH IN
THE “OFF” POSITION
IMPORTANT: When the machine is not in use, the switch
should be locked in the “OFF” position to prevent
unauthorized use. This can be done by grasping the
switch toggle (B) and pulling it out of the switch, as
shown in Fig. 19. With the switch toggle (B) removed, the
switch will not operate. However, should the switch
toggle be removed while the drill press is operating, the
switch can be turned “ O F F ” once, but cannot be
restarted without inserting the switch toggle (B).
Fig. 19
TABLE ADJUSTMENTS
1. The table can be raised or lowered on the drill press
column by loosening the table clamp (A) Fig. 20, and
turning the table raising and lowering handle (B) Fig. 21.
After the table is at the desired height, tighten clamp (A)
Fig. 20. NOTE: Final positioning of the drill press table
should always be from the bottom to the up position.
2. The table can be rotated 360 degrees on the column
by loosening clamp (A) Fig. 20, rotate table to desired
position and tighten clamp (A).
Fig. 20
Fig. 21
A
B
B
Fig. 19A
FLEXIBLE LAMP
The flexible lamp operates independently of the drill
press. To turn the lamp ON” and OFF”, rotate switch
(A) Fig. 19A.
To reduce the risk of fire, use 40 watt or
less, 120 volt, reflector track type light bulb (not supplied).
A standard household light bulb should not be used. The
reflector track type light bulb should not extend below the
lamp shade.
A