DeVillbiss Air Power Company LM7580V2C Air Compressor User Manual


 
8—ENG
INSTALLATION AND BREAK-IN PROCEDURES
This compressor should be permanently mounted in
place on a level floor. Operate the air compressor in a
clean, dry and well ventilated area. The air intake filter
must be kept clear of obstructions which could reduce air
delivery of the air compressor. The air compressor
should be located at least 12" away from walls or other
obstructions that could interfere with the flow of air
through the fan bladed flywheel. The air compressor
crankcase and head are designed with fins to provide
proper cooling.
The flywheel side of the outfit should be placed toward
the wall and protected with a totally enclosed belt guard.
In no case should the flywheel be closer than 12 to 18
inches from the wall or other obstruction that will interfere
with the flow of air through the fan bladed flywheel. The
area should allow space on all sides for air circulation
and for ease of normal maintenance. Keep the outfit
away from areas which have dirt, vapor and volatile fumes
in the atmosphere which may clog and gum the intake
filter and valves, causing inefficient operation. Where this
is not practical a remote air intake is recommended.
If humidity is high, an air filter can be installed to remove
excessive moisture. Closely follow instructions pack-
aged with the filter for proper installation. It must be
installed as close as possible to the accessory.
The air compressor should be as near to air outlets as
possible in order to avoid long pipe lines. Do not place
the air compressor where heat is excessive.
To avoid voltage drop and power loss to the motor, use
extra air hose instead of an extension cord. Low voltage
can cause damage to the motor.
Air Compressor Anchoring
Methods
THE PUMP ASSEMBLY DOES NOT PRO-
VIDE ADEQUATE STABILITY OR SUPPORT
FOR LIFTING THE UNIT. IF THE OUTFIT
MUST BE MOVED, USE THE TANK FOR
LIFTING.
VIBRATION CAN WEAKEN THE AIR TANK
AND CAUSE AN EXPLOSION. THE COM-
PRESSOR MUST BE PROPERLY MOUNTED
AS ILLUSTRATED BELOW.
Anchoring of Vertical Unit
Vertical Units
Vertical air compressors must be bolted to the floor.
Bolting holes are provided in the base feet. Mount the air
compressor on a solid, level foundation. Support com-
pressor weight evenly on all four feet. Solid shims may
be used if necessary.
ISOLATOR
WASHER
Location of the Air Compressor
Note
Where a remote air intake is used,
enlarge the size of the air intake pip-
ing by one pipe size for each 10 feet of
length.
FLAT WASHER
LAG SCREW
(NOT SUPPLIED)
TORQUE TO
5 TO 10 FT-LB