DeVillbiss Air Power Company NB2002X4 Nail Gun User Manual


 
PAGE 10
OPERATING A CONTACT TRIP
TOOL:
1. Requires finger to be off the trigger
and the nose of the Tool to be placed
on the work surface.
2. The contact trip safety mechanism is
then depressed against the work
surface and the trigger pulled to drive
a fastener.
3. The trigger is released after each
fastener is driven.
4. Move the tool to the next desired
fastener location and repeat the
procedure above.
CHECKING THE OPERATION OF
CONTACT TRIP SAFETY
MECHANISM
1. Disconnect the air supply from the tool.
2. Remove all fasteners from the
magazine.
Check the operation of the contact trip
safety mechanism often. Do not use the
tool if the contact trip safety mechanism
is not working correctly.
Make sure not to pull the trigger or
depress the contact trip safety mecha-
nism when connecting the tool to an
air compressor. Serious personal injury
or property damage can occur if the
tool cycles.
3. Make sure the trigger and contact trip
safety mechanism move up and down
without any sticking or binding.
4. Reconnect air supply to the tool.
5. Depress the contact trip safety mecha-
nism against the work surface without
pulling the trigger. The tool must not
cycle. Do not use the tool if a cycle
occurs.
6. Hold the tool clear of the work surface.
The contact trip safety mechanism
should return to its original down
position. Pull the trigger. The tool must
not cycle. Do not use the tool if a cycle
occurs.
7. Depress the contact trip safety
mechanism against the work surface.
Pull the trigger. The tool must cycle.
Disconnect tool from air supply before
adjusting, clearing jams, servicing, relo-
cating or during non-operation. Failure to
do so could result in serious injury or
property damage.
Never place your hand or any part of your
body in the fastener discharge area of the
tool when air supply is connected to the
tool. Serious personal injury may occur.
LOADING THE TOOL