4. Push release button (if equipped) and
slide feeder shoe forward.
Protect your eyes and ears. Wear Z87
safety glasses with side shields. Wear
hearing protection. Employers and users
are responsible for ensuring the user or
anyone near the tool uses the prescribed
safety equipment.
READ THIS MANUAL AND UNDERSTAND
ALL SAFETY WARNINGS AND INSTRUC-
TIONS BEFORE OPERATING TOOL.
OPERATING THE TOOL
Disconnect tool from air compressor be-
fore adjusting, clearing jams, servicing,
relocating and during non-operation. Fail-
ure to do so could result in serious injury or
property damage.
NOTE
Check and replace any damaged or
worn components on the tool. The safety
warning labels on the tool must also be
replaced if they are not legible.
1. Add one drop of DeVilbiss AC230 Air
Tool Oil, high speed spindle oil, such
as Unocal RX22, or 3-in1 oil into the
air inlet.
2. Connect the Tool to the air supply.
3. Regulate the air pressure to obtain a
minimum of 75 PSI at the tool.
4. Set air pressure regulator to 75 PSI and
test for proper fastener penetration by
driving fasteners into a sample piece of
Release Button
Feeder
wood. If the fasteners do not achieve the
desired penetration, adjust the air
pressure to a lower or higher setting
until the desired penetration is achieved.
Do not exceed the maximum operating
PSI at the tool.
NOTE: When loaded with Brad Nails, the
NBSNC2x4 will leave a 1/4 inch indention.
Tilting the tool to the left 10° will eliminate
the indention.