10
AIR INTAKE FILTER
The filter (J) is designed to clean air entering the pump. To ensure
the pump continually receives a clean, cool, and dry air supply the
filter must always be clean and the filter intake must be free from
obstructions.
MOTOR OVERLOAD PROTECTOR
The motor has a thermal overload protector. If the motor overheats
for any reason, the overload protector will shut off the motor. The
motor must be allowed to cool down before restarting. To restart:
1. Set the Auto/Off lever to OFF and unplug unit.
2. Allow the motor to cool.
3.
Plug the power cord into the correct branch circuit receptacle.
4. Set the Auto/Off lever to AUTO position.
INSTALLING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Grasp the hose at the quick connect plug and push the plug
into the quick connect body (E). Coupler will snap into place.
3. Grasp the hose and pull to ensure coupler is seated.
DISCONNECTING HOSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads 0 psi.
2. Pull coupler on quick connect body back to release Quick
Connect plug on hose.
WARNING: Risk of Electrical Shock. In the event of a short
circuit, grounding reduces the risk of shock by providing an escape
wire for the electric current. This air compressor must be properly
grounded.
The portable air compressor is equipped with a cord having a
grounding wire with an appropriate grounding plug.
1. The cord set and plug (M) with this unit
L
M
K
contains a grounding pin (L). This plug
MUST be used with a grounded
outlet (K).
IMPORTANT: The outlet being used must
be installed and grounded in accordance
with all local codes and ordinances.
2. Ensure the outlet being used has the same configuration as the
grounded plug. DO NOT USE AN ADAPTER.
3. Inspect the plug and cord before each use. Do not use if there
are signs of damage.
4. If these grounding instructions are not completely understood, or
if in doubt as to whether the compressor is properly grounded,
have the installation checked by a qualified electrician.
DANGER: Risk of Electrical Shock. IMPROPER GROUNDING
CAN RESULT IN ELECTRICAL SHOCK.
• Donotmodifytheplugprovided.Ifitdoesnotfittheavailable
outlet, a correct outlet should be installed by a qualified
electrician.
• RepairstothecordsetorplugMUSTbemadebyaqualified
electrician.