Emerson CMF200A Stud Sensor User Manual


 
Installation Manual 13
Mounting the Sensor
Figure 10 Mounting the temperature extender onto the sensor
Mounting the electronics of high-temperature and extreme high-temperature sensors
High-temperature and extreme high-temperature ELITE sensors come with a 32 (812 mm) pre-installed
flexible conduit. This conduit is required for agency approval.
A factory-supplied Model 2400S transmitter, Model 1700/2700 transmitter, core processor, or junction box is
connected to the end of the flexible conduit. Mount the electronics to a wall or instrument pole using the
supplied bracket (Figure 11).
Extended mount — carefully align the notches at
the bottom of the extended mount with the
notches on the feedthrough to engage properly
Plastic plug — remove and
discard
Feedthrough — note the
notches for correct
engagement of the extender
Clamping ring screw —
when extender is engaged,
tighten this to 13–18 in-lbs
(1.5–2 N-m)
Model 2400S transmitter or enhanced core
processor — preinstalled on the extended
mount