Fujitsu MHC2032AT Drill User Manual


 
5.3 Host Commands
C141-E050-02EN 5-63
At command issuance (I-O register contents)
1F7
h
(CM)
1 1 1 1 0 1 0 0
1F6
h
(DH)
× × ×
DV
xx
1F5
h
(CH)
1F4
h
(CL)
1F3
h
(SN)
1F2
h
(SC)
1F1
h
(FR)
xx
xx
xx
xx
xx
At command completion (I-O register contents)
1F7
h
(ST)
Status information
1F6
h
(DH)
× × ×
DV
xx
1F5
h
(CH)
1F4
h
(CL)
1F3
h
(SN)
1F2
h
(SC)
1F1
h
(ER)
xx
xx
xx
xx
Error information
(31) SECURITY FREEZE LOCK (F5h)
This command puts the device into FROZEN MODE. The following commands
used to change the lock function return the Aborted Command error if the device
is in FROZEN MODE.
SECURITY SET PASSWORD
SECURITY UNLOCK
SECURITY DISABLE PASSWORD
SECURITY ERASE UNIT
FROZEN MODE is canceled when the power is turned off. If this command is
reissued in FROZEN MODE, the command is completed and FROZEN MODE
remains unchanged.
Issuing this command during LOCKED MODE returns the Aborted Command
error.
The following medium access commands return the Aborted Command error
when the device is in LOCKED MODE: