Fujitsu MHD2021AT Drill User Manual


 
Interface
5-60 C141-E050-02EN
Check sum
Two’s complement of the lower byte, obtained by adding 511-byte data one
byte at a time from the beginning.
Insurance failure threshold
The limit of a varying attribute value. The host compares the attribute values
with the thresholds to identify a failure.
(28) SECURITY DISABLE PASSWORD (F6h)
This command invalidates the user password already set and releases the lock
function.
The host transfers the 512-byte data shown in Table 5.10 to the device. The
device compares the user password or master password in the transferred data with
the user password or master password already set, and releases the lock function if
the passwords are the same.
Although this command invalidates the user password, the master password is
retained. To recover the master password, issue the SECURITY SET
PASSWORD command and reset the user password.
If the user password or master password transferred from the host does not match,
the Aborted Command error is returned.
Issuing this command while in LOCKED MODE or FROZEN MODE returns the
Aborted Command error.
(The section about the SECURITY FREEZE LOCK command describes
LOCKED MODE and FROZEN MODE.)