Fusion L50B PRO Battery Charger User Manual


 
10
PB CHARGE
C=3.0A 12Vpack
BATT TYPE
ENTER
PB CHARGE
C=3.0A 12Vpack
INC DEC
START
BATTERY CHECK
WAIT PLEASE....
CHG 0:00 00000
PB + 3.0 A 12.000V
PB CHARGE
C=3.0A 12Vpack
INC DEC
to NiCd charge
ENTER
Setting Charge Current
Adjust the desired charge current, which ranges from 0.1A to
6.0A with the INC & DEC buttons. Press the ENTER button to
confirm the setting.
Setting Battery Voltages For a Lead-Acid (Pb)
Battery Pack
Select the correct total battery voltage to be charged with the
INC & DEC buttons – 2V, 4V, 6V, 8V, 10V, and 12V [Vpack].
PB CHARGE
C=3.0A 12Vpack
PB CHARGE
C=3.0A 12Vpack
Pb Mode