Fusion L50B PRO Battery Charger User Manual


 
6
NiCd CHARGE
C=3.0A
BATT TYPE
NiCd CHARGE
C=3.0A
START
BATTERY CHECK
WAIT PLEASE....
CHG 0:00 00000
NC+3.00A 5.200V
INC
DEC
ENTER
INC DEC
NiCd delta-peak-
volt = 0mV/cell
NiCd delta-peak-
volt = 0mV/cell
ENTER
INC DEC
Setting Charge Current
Adjust the desired charge current, which ranges from 0.1A to
6.0A with the INC & DEC buttons. Press the ENTER button to
confirm the setting.
Setting Delta Peak Sensitivity
Set the Delta Peak Sensitivity from 5mV to 25mV per cell with
the INC & DEC buttons and press the ENTER button to confirm
the setting.
NiCd CHARGE
C=3.0A
NiCd delta-peak-
volt = 0mV/cell
NiCd Mode
• When the charger is connected to the power source the charger will show the
battery mode that was last used.
• If the battery TYPE button is briefly pressed, the present battery type (NiCd, NiMH,
Lithium, or Pb ) will flash. While the existing battery type is flashing, every time
the battery TYPE button is pressed, the following modes are shown in order:
• If the other buttons are pressed, or nothing is pressed, the present battery type
stops flashing.
• If the Battery TYPE button is pressed and briefly held, the recent & previous data
will be shown until the Battery TYPE button is pressed.
• If the ENTER button is briefly pressed, a parameter which can be adjusted starts
to flash and if the ENTER button is pressed again, the next parameter starts to
flash. If nothing is pressed for 3 seconds, the parameter stops flashing.
• Once the ENTER button is pressed and briefly held, the charger starts to charge
according to the selected parameters.
NiCd CHARGE
C=3.0A
BATT TYPE
NiMH CHARGE
C=3.0A
BATT TYPE
LiIo CHARGE 3.0A
C=3000mAh 10.8Vp
BATT TYPE
Pb CHARGE
C=3.0A 12V Pack
BATT TYPE
OpErAtion
progrAmming