GE MM300 Dust Collector User Manual


 
16 MM300 MOTOR MANAGEMENT SYSTEM – COMMUNICATIONS GUIDE
RS485 INTERFACE (MODBUS RTU) COMMUNICATIONS GUIDE
EVENT RECORDER
30659 0292 Event Recorder Last Reset 2
words
--- --- --- --- F18 N/A 2
30661 0294 Total Number of Events Since
Last Clear
--- --- --- --- F1 N/A 1
30662 0295 Cause --- --- --- --- FC134 N/A 1
30663 0296 Contactor --- --- --- --- FC136 N/A 1
30664 0297 Time --- --- --- --- F19 N/A 2
30666 0299 Date --- --- --- --- F18 N/A 2
30668 029B Ia --- --- --- A F10 N/A 2
30670 029D Ib --- --- --- A F10 N/A 2
30672 029F Ic --- --- --- A F10 N/A 2
30674 02A1 Motor Load --- --- --- x FLA F3 N/A 1
30675 02A2 Iunb --- --- --- % F1 N/A 1
30676 02A3 Ig --- --- --- A F10 N/A 2
30678 02A5 Vab --- --- --- V F1 N/A 1
30679 02A6 Vbc --- --- --- V F1 N/A 1
30680 02A7 Vca --- --- --- V F1 N/A 1
30681 02A8 Van --- --- --- V F1 N/A 1
30682 02A9 Vbn --- --- --- V F1 N/A 1
30683 02AA Vcn --- --- --- V F1 N/A 1
30684 02AB Freq --- --- --- Hz F3 N/A 1
30685 02AC Power Factor --- --- --- --- F21 N/A 1
30686 02AD Real Power --- --- --- kW F13 N/A 2
30688 02AF Reactive Power --- --- --- kvar F13 N/A 2
30690 02B1 Apparent Power --- --- --- kVA F2 N/A 1
30691 02B2 Hottest Stator RTD --- --- --- --- F1 N/A 1
30692 02B3 Hottest Stator RTD --- --- --- °C F4 N/A 1
30693 02B4 Reserved --- --- --- --- --- --- 1
▼▼
30951 03B6 Reserved 1
STATUS BUFFER
30952 03B7 Alarm Status 4 --- --- --- --- FC182 N/A 2
30954 03B9 Alarm Status 3 --- --- --- --- FC181 N/A 2
30956 03BB Alarm Status 2 --- --- --- --- FC180 N/A 2
30958 03BD Alarm Status 1 --- --- --- --- FC179 N/A 2
30960 03BF Trip Status 4 --- --- --- --- FC186 N/A 2
30962 03C1 Trip Status 3 --- --- --- --- FC185 N/A 2
30964 03C3 Trip Status 2 --- --- --- --- FC184 N/A 2
30966 03C5 Trip Status 1 --- --- --- --- FC183 N/A 2
30968 03C7 Message Status 4 --- --- --- --- FC190 N/A 2
30970 03C9 Message Status 3 --- --- --- --- FC189 N/A 2
30972 03CB Message Status 2 --- --- --- --- FC188 N/A 2
30974 03CD Message Status 1 --- --- --- --- FC187 N/A 2
30976 03CF Ctrl Element Status 4 --- --- --- --- FC194 N/A 2
30978 03D1 Ctrl Element Status 3 --- --- --- --- FC193 N/A 2
30980 03D3 Ctrl Element Status 2 --- --- --- --- FC192 N/A 2
Modbus Hex Description Min Max Step Units Format Default Size in
Words