ZV370YSS—30" Professional Vent Hood
Dimensions and Specifications (in inches)
Wall Mount Framing:
Note: A decorative duct cover is available for wall mount
installations. The duct cover conceals the duct run from
the top of the hood to the ceiling. Choose the 6" or 12"
cover based upon installation height of the vent hood.
We recommend that the vent hood and decorative duct
cover be on site before final framing and wall finishing in
order to accurately locate the ductwork and electrical
service.
• Determine the location for installation.
• Mark the centerline of the installation.
Cut a sheet of plywood 30" wide and 18" high. If drywall
is installed, cut away enough to expose two vertical
studs, one on each side of the cutout. Secure the plywood
to the studs.
• Install additional aligning wall studs as illustrated.
No Additional
Wall Studs needed
Plywood Sheet
(Wall Hole Cut
Out x Drywall
Thickness)
Hood
Width
7" Min.
Additional
Wall Studs
Installed
Centerline of
Installation
Space
7" Min.
Hood
Width
8-15/16” 8-15/16”
C
L
6" or 12"
Duct
Cover
Ceiling Drywall
Rear View of Vent Hood
18"
Hood Centerline
6-1/2"
2-1/2"
6-1/2"