ROUTINE YEARLY
Lubricate the drive screw:
s Wipe off old grease using a lint-free cloth.
s Apply a light coating of silicon based grease
(For best results, use Genie® GLU-R).
9
©2011 The Genie Company
9/2011
CORRECTIVE MAINTENANCE
TO ENGAGE, PULL
DOWN AND TOWARD
THE OPENER. THEN LET GO.
TO DISENGAGE, PULL
DOWN ON THE RELEASE
HANDLE AND LET GO.
DISENGAGING AND ENGAGING CARRIAGE
CHANGE LIGHT BULBS
WARNING
s When replacing light cover, make sure wires are
not pinched or near moving parts.
s Use extreme caution when working from a ladder
or step stool.
1. Disconnect power to door opener.
s/PENPowerhead light cover.
s2EMove light bulb(s).
s2EPLAce light bulb(s).
– Do NOT use light bulbs with greater than
100 Watt rating.
s#LOSEPowerhead light cover.
2. Reconnect power to door opener.
s Test light operation.
RESET - OPEN/CLOSE TRAVEL LIMIT
Performing all ten (10) Limits/Force setting steps
(page 5) erases previous Limits/Force settings.
NOTE: The opener will not close the door
automatically unless the Safe-T-Beam® System is
installed and Limits are programmed.
REMOTE BATTERY REPLACEMENT
Replace remote battery with a
CR 2032 coin cell battery.
1. Open the remote case using a
washer or coin that fits into the
slot at the top of the remote.
2. Replace battery.
3. Align components and
snap case closed.
ENGAGED
DISENGAGED
OPENER