Giant LP122A-3100 Router User Manual


 
6
LP122A-3100 - Repair Instructions
1. With a 30mm wrench, re-
move the six (6) plugs (48)
from the valve casing (43).
Inspect the o-rings (48A)
and replace if necessary.
Remove the complete valve
assembly (46A) by thread-
ing a 12mm bolt into the
spring retainer and pulling
straight out.
2. To disassemble the valve, screw the bolt into the retainer until
the valve plate (45) presses the valve seat (44) out of the spring
retainer. Examine all parts and replace if necessary. If the seat
doesn’t come out, use a valve puller to remove.
3. Remove the eight (8) hex
nuts (49A) with a 19mm
wrench. Tap the back of
the manifold (43) with a
rubber mallet to dislodge
and slide off the studs.
4. Remove the seal sleeve (35) from the manifold and/or
crankcase. Remove the pressure rings (39&36A), v-sleeves
(40&36), support ring (41) and o-rings (35A) from the
manifold and seal sleeve, respectively. Examine seals care-
fully and replace if worn. Clean all parts.
44A 44 45 48 47