11. Press seal sleeve assembly into
the manifold and seat firmly.
Put the support ring (41) on
plunger with v-side facing the
manifold.
12. Place entire manifold/seal
sleeve assembly over the studs
and push firmly until seated
against the crankcase.
15. Replace plug with o-ring (48, &
48A) and tighten to 160 ft.-lbs.
14. Next, place valve assemblies
(46A) into manifold after first
lubricating the o-ring (44A). Seat
firmly into manifold.
13. Tighten hex nuts (49A) in a
crosswise pattern (shown
above) to 60 ft.-lbs.
16. Fill crankcase with approxi-
mately 116 fluid ounces of Gi-
ant oil or equivalent SAE 90
industrial gear oil and check oil
level of the crankcase with the
dipstick. Proper level is center
of two lines. Reinstall your Gi-
ant LP pump into your system.
Contact Giant Industries or your local distributor for maintenance
of the gear end of your pump. Phone: 419/531-4600
Contact Giant Industries for service school information. Phone: (419) 531-4600
6
4 2
7
8
1
3
5
LP122A-3100 - Repair Instructions