Graco 1595 Paint Sprayer User Manual


 
10/16 Amp Switch
12 332916C
Pails
Solvent and oil/based fluids: follow local code. Use
only conductive metal pails, placed on a grounded sur-
face such as concrete.
Do not place pail on a nonconductive surface such as
paper or cardboard which interrupts grounding
continuity.
Grounding a metal pail: connect a ground wire to the
pail by clamping one end to pail and other end to a true
earth ground.
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of spray gun firmly
to side of a grounded metal pail. Then trigger gun.
10/16 Amp Switch
(Mark VII and Mark X units)
Select 10A or 16A setting based on your circuit rating.
15/20 Amp Switch
(120V 1595 and Mark V units)
Select 15A or 20A setting based on your circuit rating.
ti5850b
ti14840a
ti18247b
ti22874a
ti22936a