Graco 1595 Paint Sprayer User Manual


 
Troubleshooting
28 332916C
Sprayer does not run at all Check transducer or transducer
connections (control board is not
detecting a pressure signal).
1. Set sprayer to OFF and disconnect power to
sprayer.
2. Check transducer and connections to control board.
3. Disconnect transducer from control board socket.
Check to see if transducer and control board
contacts are clean and secure.
4. Reconnect transducer to control board socket.
Connect power, set sprayer ON and control knob
to 1/2 turn clockwise. If sprayer does not run,
set sprayer to OFF and go to next step.
5. Connect a confirmed working transducer to control
board socket.
6. Set sprayer ON and control knob to 1/2 turn
clockwise. If sprayer runs, install new transducer.
Replace control board if sprayer does not run.
7. Check transducer resistance with ohmmeter (less
than 9k ohm between red and black wires and 3-6k
ohm between green and yellow wires).
Display shows CODE 03
Control board status light blinks
3 times repeatedly
Sprayer does not run at all
Check voltage supply to the
sprayer (control board is
detecting a multiple voltage
surges).
1. Set sprayer to OFF and disconnect power to
sprayer.
2. Locate a good voltage supply to prevent damage to
electronics.
Display shows CODE 4
Control board status light blinks
four times repeatedly
TYPE OF PROBLEM WHAT TO CHECK HOW TO CHECK