Cleanup
22 332916C
Cleanup
1. Perform Pressure Relief Procedure (page 13),
steps 1 - 4. Remove tip guard from gun.
NOTE: Use water for water-base material, mineral
spirits for oil-base material, or other solvents recom-
mended by manufacturer.
2. Turn power ON. Turn prime valve forward to
SPRAY position.
3. Increase pressure to 1/2. Hold gun against pail. Dis-
engage trigger lock. Trigger gun until flushing fluid
appears.
4. Move gun to waste pail, hold gun against pail, trig-
ger gun to thoroughly flush system. Release trigger
and engage trigger lock.
5. Turn prime valve down to DRAIN position and allow
flushing fluid to circulate until flushing fluid appears
clear.
6. Turn prime valve forward to SPRAY position. Trig-
ger gun into flushing pail to purge fluid from hose.
7. Raise pump above flushing fluid and run sprayer for
15 to 30 seconds to drain fluid. Turn power OFF.
8. Turn prime valve down DRAIN position. Unplug
sprayer.
ti22943a
ti18249a
ti22944a
ti18248a
ti22945a
ti22946a
ti18248a
ti22947a
ti22945a