Setup
12 3A1698F
Sprayer Setup
This sprayer arrives from the factory with a small
amount of test material in the system. It is important
that you flush this material from the sprayer before
using it for the first time:
1. Fill material cup with water or compatible solvent,
thread onto sprayer and hand tighten.
2. Put prime/pressure relief valve to UP position, then
hold trigger in for 10 seconds.
3. Put prime/pressure relief valve DOWN to spray
position.
4. Reverse spray tip to UNCLOG position and trigger
sprayer into a waste area for 10 seconds.
5. Engage trigger lock and put prime/pressure relief
valve UP to release pressure.
6. Unscrew and remove material cup.
7. Disengage trigger lock, put prime/pressure relief
valve DOWN, hold sprayer slightly above material
cup, and pull trigger to discharge fluid from pump.
8. Put prime/pressure relief valve UP and pull trigger to
finish material flushing.
9. Discard material in cup.