Repair
38 3A2308C
Installation
1. Insert wires and tighten screws to connect wires into
slots 1 and 2 of trigger switch.
2. Install trigger over top of wires. Route trigger wires
behind trigger.
3. Install trigger lock over trigger with o-ring facing out.
4. Install bolts (42) into motor housing and install
screws (43) to connect the clamshell halves. Make
sure LED lights and static wick are properly in place.
Tighten all four bolts (42) to 50 in-lb (5.6 N•m) and
screws (43) to 9 in-lb (1 N•m).
5. Install pump module into drive module. See Pump
Module/Drive Module, page 31.
ti19648a
ti19631a
ti19632a
ti19635a
42
43