Operation
3A2308C 13
7. Reverse tip to UNCLOG position. Put prime/pres-
sure relief valve DOWN to spray position and trigger
sprayer through tip into waste area for 1- 2 seconds.
8. Engage trigger lock and put prime/pressure relief
valve UP to release pressure.
9. Remove material cup.
10. Disengage trigger lock, put prime/pressure relief
valve DOWN to spray position, hold sprayer slightly
above material cup and pull trigger to discharge fluid
from pump.
11. Put prime/pressure relief valve UP and pull trigger to
finish flushing material.
12. Properly discard any material in cup.
Install/Service Filter (if needed)
1. Perform Pressure Relief Procedure, page 9.
2. Unthread front valve housing from sprayer.
3. Filter should come out of pump housing with valve.
If filter remains in housing, remove it by hand or with
pliers if necessary.
4. Install properly-sized filter (if needed).
5. Reassemble valve housing to pump.
ti14995a
ti19346a
ti19366a
ti19370a
ti19347a
ti19350a
ti19403a
ti19401a
ti19362a
ti19342a
ti19349a
ti19364a