Graco 313255K Paint Sprayer User Manual


 
DataTrak Operation
313255K 23
Replace DataTrak Battery or Fuse
Replace Battery
1. Unscrew cable from the back of the reed switch
assembly. See F
IG. 10.
2. Remove the cable from the two cable clips.
3. Remove DataTrak module from bracket. See F
IG.
11. Take module and attached cable to a non-haz-
ardous location.
4. Remove two screws on back of module to access
battery.
5. Disconnect the used battery and replace with an
approved battery. See F
IG. 12.
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with a new fuse.
The battery and fuse must be replaced in a
non-hazardous location.
Use only the following approved replacement batter-
ies. Use of an unapproved battery will void Graco’s
warranty and FM and Ex approvals.
Ultralife lithium # U9VL
Duracell alkaline # MN1604
Energizer alkaline # 522
Varta alkaline # 4922
Use only a Graco-approved replacement fuse. Order
Part 24C580.
F
IG. 10. Disconnect DataTrak
FIG. 11. Remove DataTrak
ti11992a
ti11884a
FIG. 12. DataTrak Battery and Fuse Location
ti11994a
Battery
Fuse
Solenoid Cable
Connection
Sensor Cable
Connection