Setup
3A0156B 9
Setup
1. Standard Units Only: Connect Graco airless hose
to sprayer. Tighten securely.
2. Standard Units Only: Connect other end of hose
to gun and tighten securely.
3. Engage gun trigger safety.
4. Remove tip guard.
5. Check inlet strainer for clogs and debris.
6. Fill throat packing nut with Graco TSL to prevent
premature packing wear. Do this each time you
spray.
7. Turn power OFF.
8. Plug power supply cord into a properly grounded
electrical outlet.
9. Turn prime valve down to DRAIN position.
10. Place pump in grounded metal pail partially filled
with flushing fluid. Attach ground wire to pail and
to true earth ground. Perform steps 1 - 5 of Startup
to flush out storage oil shipped in sprayer. Use water
to flush water-base paint and mineral spirits to flush
oil-base paint and storage oil.
ti14843a
ti13031a
ti10166a
ti2769a
ti13453a
ti4265a
ti4265a
ti2810a
ti14842a
ti14844a