Graco 3A0235G Welding System User Manual


 
Installation
10 3A0235G
T2 2:1 and Monark 5:1
1. Flush pumps, page 8.
2. Position drums, page 8.
3. Open drum bung hole. Screw bung adapter with
gasket into bung hole. See pump manual.
4. Install swivel fitting (102) in pump fluid outlet. See
F
IG. 2.
5. Connect hose (103) between swivel fitting (102) and
the system swivel inlet (D, see F
IG. 1).
6. Install air supply kit and connect air lines, page 12,
to finish installation.
Husky 1050 Wall Mount
1. Be sure wall can support weight of pump, hoses,
and accessories, and can withstand stress during
operation.
2. Position wall bracket (204) no more than 5 ft (1.52
m) above floor. Check that bracket is level. Attach to
wall, using screws long enough to keep bracket from
vibrating. See F
IG. 3.
3. Connect swivel union (209) to pump inlet.
4. Install bushing (105) in pump air inlet.
5. Install pump (201) on bracket (204) securely, using
screws (211), washers (210), and nuts (212).
6. Connect elbow (210) to top of riser tube kit (202).
7. Connect suction hose (203) to elbow (210) and inlet
swivel (209).
8. Install swivel fitting (102) in pump fluid outlet. See
F
IG. 4.
9. Connect hose (103) between swivel fitting (102) and
GMS
swivel inlet fitting. See FIG. 4.
10. Install air supply kit and connect air lines, page 12,
to finish installation.
F
IG. 2. Standard 2:1 Kit
TI10281a
201
102
103
bung adapter
F
IG. 3. Husky 1050 Wall Mount
r_24D329_3a0235_1a
203
201
209
202
204
210
211
213
105
212